Modular heat pumps for cooling and heating type water-water Model TCMN - Capacities from 88 KW to 420 KW
Modular heat pump cooling water based TCMN series is a water cooler water based that Technocon provided by and is the result of many years of experience in design, production and modularization geothermal heat pumps, combining the most recent advanced technologies.
Modular heat pumps based cooling water are used in office buildings, hotels, hospitals, factories, houses, etc. It is a popular product that adhered to the concept of "efficient, reliable, energy efficient, environmentally friendly" and is suitable for outstanding products, newer and more economical.
Easy installation, simple operation opportunity valve connection option (winter heating / summer cooling) Built-powered automatic control panel with external display with manually operated valve digitals, compared with nemodulare heat pumps, pumps TCMN more profitable. Heat recovery is optional and operating temperatures are, water inlet temperature 40 ℃ and 45 ℃ output.
High efficiency, low energy consumption due to installation parallel compressors, which allows use on a wider range pump capacity, thus having a better efficiency lower power consumption.
Excellent quality of components used as compressors and accessories that are from famous international companies, ensuring a high level of performanta.Folosindu the most advanced and efficient system DAE / DAC heat transfer through the tube in tube heat exchangers, COP increase substantially. Also cooling control system, it increases the efficiency of heat exchange.
Silent Ecological heat pump type water cooled modular water works quietly and does not pollute atmostfera, use environmentally R407C refrigerant.
Safety and comfort small size, low weight and ease of installation, are only required water connections to terminal units and up to date. Compressors start at a time, thus starting current required is low, thus ensuring safety and operation and performance. Redundancy is good because if a fault on one circuit, the other operates independently termic.Toate not affect yield components are protected enclosure so it chic electric gas system are protected from any accidente.Microcomputerul automatic control system controls the high pressure or low, overload, phase loss, low temperature, etc. External pump has a function and a display for display and reporting errors.
Technical specifications
Model |
TCMN80 |
TCMN120 |
TCMN180 |
TCMN280 |
TCMN380 |
||
Capacitate racire |
kW |
76 |
114 |
163 |
261 |
366 |
|
Consum nominal racire |
kW |
15 |
23 |
32 |
52 |
73 |
|
Capacitate incalzire |
kW |
88 |
131 |
186 |
300 |
420 |
|
Consum nominal incalzire |
kW |
19 |
29 |
41 |
64 |
89 |
|
Curent max functionare |
A |
40 |
60 |
80 |
120 |
160 |
|
Compresor Tip |
Full-Hermetic Scroll |
||||||
Tensiune de alimentare |
V/Ph/Hz |
380/3/50 |
|||||
Refrigerant |
R407C |
||||||
Refrigerant Cantitate |
kG |
14 |
21 |
29 |
42 |
56 |
|
Debit apa circuit primar |
Rece Evaporator |
m3/h |
7 |
11 |
16 |
25 |
35 |
Calda Condensator |
m3/h |
13 |
20 |
29 |
46 |
63 |
|
Debit apa circuit secund |
Rece Condensator |
m3/h |
13 |
20 |
29 |
46 |
63 |
Calda Evaporator |
m3/h |
7 |
11 |
16 |
25 |
35 |
|
Cadere presiune pe condensator |
Racire |
kPa |
22 |
22 |
30 |
30 |
30 |
Incalzire |
kPa |
50 |
50 |
65 |
65 |
65 |
|
Cadere presiune pe evaporator |
Racire |
kPa |
50 |
50 |
65 |
65 |
65 |
Incalzire |
Kpa |
22 |
22 |
30 |
30 |
30 |
|
Opt Recuperator caldura |
Capacitate |
KW |
16 |
24 |
34 |
55 |
77 |
Debit ACM |
m3/h |
3 |
4 |
6 |
9 |
12 |
|
Cadere presiune ACM |
Kpa |
28 |
32 |
35 |
38 |
40 |
|
Capacitate totala recuperator caldura |
KW |
90 |
130 |
190 |
300 |
410 |
|
Debit total recuperator caldura ACM |
m3/h |
15 |
22 |
32 |
51 |
71 |
|
Cadere totala presiune recuperator ACM |
Kpa |
115 |
115 |
69 |
69 |
68 |
|
Racorduri hidraulice Dimensions |
DN65 |
DN65 |
DN65 |
DN65 |
DN65 |
||
Lungime |
mm |
1730 |
1730 |
1880 |
2250 |
2250 |
|
Adancime |
mm |
950 |
1200 |
1200 |
1700 |
1700 |
|
Inaltime |
mm |
1450 |
1450 |
1450 |
1450 |
1450 |
|
Greutate |
kG |
550 |
750 |
1000 |
1720 |
2300 |
Nota
Conditii standard pe circuitul primar in regim de racire: temperatura de intrare apa 12℃ , temperatura de iesire 7℃ .
Conditii standard pe circuitul secundar in regim de racire: temperatura de intrare apa 18℃ , temperatura de iesire 29℃.
Conditii standard pe circuitul secundar in regim de incalzire: temperatura de intrare 40℃, temperatura de iesire 15℃
Presiunea maxima pe circuitul de apa: 1.0 Mpa
Detaliile tehnice se pot modifica fara o notificare prealabila